Some news.....
It is not caused by transmission lines, conectors or anything like that.
The telco tecnician just came here and analyzed the circuit and he got no erros!
He sugested me to loop my PRI port in the balum attached in my asterisk box. And.... Surprise...
I got the same errors! The error is on my hardware/software.
[]s Alex Robertson
Alex G Robertson wrote:
Hi everybody,
I just installed asterisk, but this NOTICE dont stop appearing on my log file;;
Feb 17 18:30:11 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:29:42 NOTICE[1336]: PRI got event: HDLC Abort (6) on Primary D-channel of span 4
Feb 17 18:29:41 NOTICE[1336]: PRI got event: HDLC Abort (6) on Primary D-channel of span 4
Feb 17 18:29:41 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:27:11 NOTICE[1336]: PRI got event: HDLC Abort (6) on Primary D-channel of span 4
Feb 17 18:26:51 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:25:11 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:24:41 NOTICE[1336]: PRI got event: HDLC Abort (6) on Primary D-channel of span 4
Feb 17 18:22:21 NOTICE[1336]: PRI got event: HDLC Abort (6) on Primary D-channel of span 4
Feb 17 18:21:16 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:15 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:15 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:15 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:15 NOTICE[1336]: PRI got event: HDLC Abort (6) on Primary D-channel of span 4
Feb 17 18:21:15 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:14 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:14 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:14 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:13 NOTICE[1336]: PRI got event: HDLC Abort (6) on Primary D-channel of span 4
Feb 17 18:21:12 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:11 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
Feb 17 18:21:01 NOTICE[1336]: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 4
And from time to time this is happening....
-- B-channel 0/1 successfully restarted on span 4 -- B-channel 0/2 successfully restarted on span 4 -- B-channel 0/3 successfully restarted on span 4 -- B-channel 0/4 successfully restarted on span 4 [...] -- B-channel 0/29 successfully restarted on span 4 -- B-channel 0/30 successfully restarted on span 4 -- B-channel 0/31 successfully restarted on span 4
And the conversation stops.
Telco, with a traffic analyzer, says that the clock is sliding.
Does anybody knows what can it be? Hardware, software, transmission (conectors) etc.... ?
Thanks in advance.
-- Alex G Robertson NOC - Microlink
_______________________________________________ Asterisk-Users mailing list [email protected] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users