I have a TE205P that has been working fine for 2 years.
power outage yesterday took out my everything for over an hour.

Everything has come back up except the PRI. My provider has checked it 
to the box
and says everything looks good on their end.

I get this message:
[Jul  9 12:40:32] WARNING[13709] chan_dahdi.c: No D-channels available!  
Using Primary channel 24 as D-channel anyway!

ztcfg -vvv

Zaptel Version: 1.4.12.1
Echo Canceller: MG2
Configuration
======================

SPAN 1: ESF/B8ZS Build-out: 0 db (CSU)/0-133 feet (DSX-1)

Channel map:

Channel 18: Clear channel (Default) (Slaves: 18)
Channel 19: Clear channel (Default) (Slaves: 19)
Channel 20: Clear channel (Default) (Slaves: 20)
Channel 21: Clear channel (Default) (Slaves: 21)
Channel 22: Clear channel (Default) (Slaves: 22)
Channel 23: Clear channel (Default) (Slaves: 23)
Channel 24: D-channel (Default) (Slaves: 24)

7 channels to configure.

and show status gives me condition RED of course.

How do I find out whats wrong here?

Jerry

-- 