Ahhhh.  Second CSECT had an expression on the END statement.

On Tue, Mar 14, 2023 at 4:01 PM Dave Clark <[email protected]> wrote:

> "IBM Mainframe Assembler List" <[email protected]> wrote on
> 03/14/2023 04:51:16 PM:
> > I had 2 ASM steps and a LKED step (with no ENTRY statement).  Binder
> > assigned entry point to second CSECT (nonzero location).  WAD?
>
>
>         That happens to me if I leave the END statement blank with no
> entry point specified.
>
>
> Sincerely,
>
> Dave Clark
> --