Yes, here you go...
Active Usings: None
D-Loc Object Code Addr1 Addr2 Stmt Source Statement
HLASM R6.0 2016/11/11 09.23
00000B50 00000040 7223 WKCHAR0 EQU
WKMSGWK0,L'WKMSGWK0,C'X' work area 0
00000B90 00000040 7224 WKCHAR1 EQU
WKMSGWK1,L'WKMSGWK1,C'X' work area 1
00000BD0 00000040 7225 WKCHAR2 EQU
WKMSGWK2,L'WKMSGWK2,C'X' work area 2
00000C10 00000040 7226 WKCHAR3 EQU
WKMSGWK3,L'WKMSGWK3,C'X' work area 3
00000C50 00000040 7227 WKCHAR4 EQU
WKMSGWK4,L'WKMSGWK4,C'X' work area 4
00000C90 00000040 7228 WKCHAR5 EQU
WKMSGWK5,L'WKMSGWK5,C'X' work area 5
00000CD0 00000040 7229 WKCHAR6 EQU
WKMSGWK6,L'WKMSGWK6,C'X' work area 6
00000D10 00000040 7230 WKCHAR7 EQU
WKMSGWK7,L'WKMSGWK7,C'X' work area 7
00000D50 00000040 7231 WKCHAR8 EQU
WKMSGWK8,L'WKMSGWK8,C'X' work area 8
00000D90 00000040 7232 WKCHAR9 EQU
WKMSGWK9,L'WKMSGWK9,C'X' work area 9
00000B50 00000100 7233 WKMISCTR EQU
WKMSGWK0,256,C'X' use 1st 4 wk fields for misc TR table
Chuck
Charles (Chuck) Hardee
Senior Systems Engineer/Database Administration
EAS Information Technology
Thermo Fisher Scientific
300 Industry Drive | Pittsburgh, PA 15275
Phone +1 (724) 517-2633 | Mobile +1 (412) 877-2809 | FAX: +1 (412) 490-9230
[email protected] | www.thermofisher.com
WORLDWIDE CONFIDENTIALITY NOTE: Dissemination, distribution or copying of this
e-mail or the information herein by anyone other than the intended recipient,
or an employee or agent of a system responsible for delivering the message to
the intended recipient, is prohibited. If you are not the intended recipient,
please inform the sender and delete all copies.
-----Original Message-----
From: IBM Mainframe Assembler List [mailto:[email protected]] On
Behalf Of Thomas David Rivers
Sent: Wednesday, November 16, 2016 7:49 AM
To: [email protected]
Subject: Addr2 field in listing for EQU statement?
In the HLASM documentation it indicates what
should be present in the Addr2 field of the listing.
In particular, it says:
The field headed Addr2 contains the effective
address of the last operand of any instruction
referencing storage.
- For a USING instruction, the Addr2 field
contains the value of the second operand.
- For a CSECT, START, LOCTR, or RSECT instruction,
the Addr2 field contains the end address of
the control section.
- For an ORG instruction, the Addr2 field contains
the next address as specified by the operand field.
- For an EQU instruction, the Addr2 field contains
the length assigned.
Note that last statement, where it indicates the Addr2
field contains the length assigned for an EQU instruction.
I can't seem to get HLASM to actually do that; and
I've tried a few variants. For me, the Addr2 field
of any EQU instruction is always empty.
Does anyone have an example where the Addr2 field
of an EQU instruction is _not_ empty?
- Many thanks -
- Dave Rivers -
--
[email protected] Work: (919) 676-0847
Get your mainframe programming tools at http://www.dignus.com