Hi Assembler gurus,
I use the code below to dynamically allocate a PDS member. This works fine if
the member does not exist. If it does (& I wish to append to it), it fails with
a B14-04.
I thought that Text Unit id=4 with a value of X'02' indicated I wanted to use
DISP=MOD. What do I need to change in order to be able to append to an existing
PDS member?
As an aside, is there a better way of doing this?
DYNA DC 0F'0',X'80',AL3(DYNARB1) RB POINTER
DYNARB1 DS 0F ALIGN
DC AL1(20),AL1(01),AL2(0) LENGTH,ALLOC-VERB,FLAGS1
DYNAER DC AL2(0) ERROR CODE
DYNAIN DC AL2(0) INFO CODE
DC A(DYNATU) TEXT UNIT LIST POINTER
DC A(0) RESERVED
DC A(0) FLAGS2
DYNATU CALL ,(D11,D12,D13,D14,D15),VL,MF=L TU POINTERS
D11 DC XL2'1',XL2'1',XL2'8',CL8'CNTL ' DDNAME
D12 DC XL2'2',XL2'1',XL2'2C',CL44' ' DSNAME
D13 DC XL2'3',XL2'1',XL2'8',CL8'CSV' MEMBERNAME
D14 DC XL2'4',XL2'1',XL2'1',XL1'02' DISP=(MOD...
D15 DC XL2'5',XL2'1',XL2'1',XL1'08' ...,KEEP)
DSNAME EQU D12+6,44
DSNMEMB EQU D13+9,5
Regards - Grant.