From: Dillon Varone <[email protected]>

[WHY&HOW]
Address was not previously populated which can result in incorrect
clock frequencies being read on boot.

Reviewed-by: Alvin Lee <[email protected]>
Signed-off-by: Dillon Varone <[email protected]>
Signed-off-by: Wayne Lin <[email protected]>
---
 drivers/gpu/drm/amd/display/dc/clk_mgr/dcn401/dcn401_clk_mgr.c | 2 ++
 drivers/gpu/drm/amd/display/dc/inc/hw/clk_mgr_internal.h       | 1 +
 2 files changed, 3 insertions(+)

diff --git a/drivers/gpu/drm/amd/display/dc/clk_mgr/dcn401/dcn401_clk_mgr.c 
b/drivers/gpu/drm/amd/display/dc/clk_mgr/dcn401/dcn401_clk_mgr.c
index 8082bb877611..a3b8e3d4a429 100644
--- a/drivers/gpu/drm/amd/display/dc/clk_mgr/dcn401/dcn401_clk_mgr.c
+++ b/drivers/gpu/drm/amd/display/dc/clk_mgr/dcn401/dcn401_clk_mgr.c
@@ -24,6 +24,8 @@
 
 #include "dml/dcn401/dcn401_fpu.h"
 
+#define DCN_BASE__INST0_SEG1                       0x000000C0
+
 #define mmCLK01_CLK0_CLK_PLL_REQ                        0x16E37
 #define mmCLK01_CLK0_CLK0_DFS_CNTL                      0x16E69
 #define mmCLK01_CLK0_CLK1_DFS_CNTL                      0x16E6C
diff --git a/drivers/gpu/drm/amd/display/dc/inc/hw/clk_mgr_internal.h 
b/drivers/gpu/drm/amd/display/dc/inc/hw/clk_mgr_internal.h
index 7a1ca1e98059..221645c023b5 100644
--- a/drivers/gpu/drm/amd/display/dc/inc/hw/clk_mgr_internal.h
+++ b/drivers/gpu/drm/amd/display/dc/inc/hw/clk_mgr_internal.h
@@ -221,6 +221,7 @@ enum dentist_divider_range {
        CLK_SF(CLK0_CLK_PLL_REQ, FbMult_frac, mask_sh)
 
 #define CLK_REG_LIST_DCN401()    \
+       SR(DENTIST_DISPCLK_CNTL), \
        CLK_SR_DCN401(CLK0_CLK_PLL_REQ,   CLK01, 0), \
        CLK_SR_DCN401(CLK0_CLK0_DFS_CNTL, CLK01, 0), \
        CLK_SR_DCN401(CLK0_CLK1_DFS_CNTL,  CLK01, 0), \
-- 
2.37.3